General Cable
Fire Alarm Cable Solutions
Multi-Conductor • Unshielded • Riser Rated
General Cable Fire Alarm Cable

Fire Alarm Cable
Un-Shielded FPLR

NEC FPLR
CL3R
CMR
Solid Bare Copper • S-R PVC • Red Jacket
Riser-rated fire alarm cable for vertical runs and general fire protective circuits in non-plenum applications
✓
Riser Rated
UL 1666
🔥
300V Rated
75°C UL
📏
Sequential
Footage Marks
⚡
Solid Copper
ASTM B3
Available Configurations (Base Part #)
18 AWG 2-Conductor
GCCE1502S*
18 AWG 4-Conductor
GCCE1504S*
16 AWG 2-Conductor
GCCE1512S*
16 AWG 4-Conductor
GCCE1514S*
14 AWG 2-Conductor
GCCE1522S*
14 AWG 4-Conductor
GCCE1524S*
12 AWG 2-Conductor
GCCE1532S*
📋 Part Number Format
Complete part #: GCCE1502S.XX.YY where XX = Put-up code (.30=1000' box, .41=1000' reel) and YY = Color code (.03=Red). Example: GCCE1502S.41.03 = 18/2C, 1000' reel, red jacket. See back for all options.
Voltage
300V
Temp Range
-20 to 75°C
Conductor
Solid Cu
Pull card → Counter → Specify AWG, conductors & put-up

Fire Alarm Cable FPLR

General Cable • Un-Shielded Riser
Part Number Format: GCCE1502S.XX.YY
Put-Up Codes (XX)
.12 100' Pull-Pac
.15 250' Pull-Pac
.18 500' Reel
.30 1000' Pull-Pac
.41 1000' Reel
.46 5000' Reel
Color Codes (YY)
.01 Black
.02 White
.03 Red (Standard)
.04 Orange
.05 Yellow
.07 Blue
Cable Specifications
Part #
AWG
Cond.
Ins. Thick
Nom. OD
E1502S
18
2C
0.010"
0.150"
E1504S
18
4C
0.010"
0.175"
E1512S
16
2C
0.010"
0.172"
E1514S
16
4C
0.010"
0.202"
E1522S
14
2C
0.013"
0.210"
E1524S
14
4C
0.013"
0.248"
E1532S
12
2C
0.013"
0.244"
Key Features
  • Fully annealed solid bare copper per ASTM B3
  • Premium-grade S-R PVC insulation
  • Premium-grade PVC red jacket
  • Sequential footage markings
  • Includes ripcord for easy stripping
  • Extended temp range: -20°C to +75°C
  • NEC Article 760 Type FPLR rated
  • NEC Article 725 Type CL3R rated
  • NEC Article 800 Type CMR rated
  • Designed to meet UL 1666 flame test
  • California compliant
  • RoHS Compliant 2011/65/EU
🔥 Applications
Fire alarm systems • Smoke detectors • Voice communications • Burglar alarms • Fire protective circuits • Vertical riser runs in non-plenum spaces • General fire safety wiring
💡 Riser vs. Plenum Rating
FPLR (Riser) is for vertical runs between floors in non-plenum spaces and general fire alarm wiring. Use FPLP (Plenum) for air handling spaces above drop ceilings and HVAC plenums. Riser-rated cable meets UL 1666 flame test vs. NFPA 262 for plenum. Choose based on installation environment and local code requirements.
📋 Ordering Example
GCCE1502S.41.03 = 18 AWG, 2-Conductor, 1000' Reel (.41), Red Jacket (.03). Contact Mayer for availability of specific put-up and color combinations. Standard stocking: Red jacket (.03) in common put-ups.
Scan for product details
Scan for Info
Mayer Electric Supply
Please return this card to the display after ordering